INSTALLATION ContdOPERATING INSTRUCTIONS
WALL CABINET FITTINGThe cooker hood functions are controlled by
Before fitting the cooker hood beneath anytwo slide switches and a change-over slider
type of wall cabinet ensure it is firmly fixed tocontrol. The two slide switches, which are
the wall in accordance with the manufacturerslocated on the right hand side in the front
instructions.fascia panel, control the fan speed and
worktop illumination.
Use the paper template provided to mark theThe change-over slider control is located inside
hole positions on the underside of the cabinet.the hood behind the inlet grille immediately in
When marking the underside of the cabinetfront of the lamp assembly.
the front edge of the template must be alignedEnsure the hood is in, or wired in and the
with the front edge of the cabinet carcase.power supply is switched on.
The switch marked with the lamp symbol and
Check the distances of the holes are correctnumbered 0-1 controls the worktop lighting.
with a tape measure as stated on the template.Position -1 indicates the light is operating.
The four holes are 5mm (1/4") dia.The switch marked with the fan symbol and
numbered 0-1-2-3 controls the fan speed, -1
A pad saw or similar cutter will be required toLow, -2 Normal and -3 Boost.
cut the circular hole for the ducting spigot if it
is to be used.Position -1 Should be selected when
simmering or when using one pan.
Insert the fixing screws through the holes fromPosition -2 Should be selected for normal
inside the cabinet. Supporting the cooker hoodcooking up to four pans.
tighten each screw about half way to ensurePosition -3 Should be selected when frying
that the cooker hood is correctly positionedor cooking food with strong odour.
before fully tightening the screws.
In the recirculation position, slider towards the
charcoal filter, air enters the cooker hood,
DUCTING FITTINGpasses through the grease and charcoal filter
If the hood is to be ducted to the outside thenand out through the holes in front of the casing
the blanking plate supplied must be fitted intop panel.
the aperture that will not be used.To convert the hood from extraction to
recircula-tion open the metal inlet grille and
Fit the ducting spigot into the selected apertureslide the change-over control to the right.
and make an air tight connection.Remove the thumb screw from the motor
support. Take the charcoal filter and place it
To fit the ducting spigot and blanking plate alignover the motor support and secure by passing
the inter-locking lugs on the fitting with thethe thumb screw through the hole in the filter
recesses in the aperture and insert turningand into the captivated nut in the centre of
clockwise to lock the spigot and blanking platethe motor support.
into position.
In the ducting position, slider away from the
The ducting used must be 100mm (4")charcoal filter, the air passes through the
diameter and be manufactured from firegrease filter and out through ducting to the
retardent material conforming to the relevantatmosphere. When the ducting position is
British Standard or DIN 4102-B1.selected, the charcoal filter is not required.
Where flexible ducting is fitted it should notNOTE: The hood is more effective when used
be turned through very tight bends as thisin the extraction (ducting) mode, therefore this
could impair the performance of the hood. (Theposition should be selected during the warmer
o
maximum length of ducting including one 90months of the year when no room heating is
bend should be 3 metres, to be reduced by 1required. When the room is being heated if the
metre for each 90 degree bend installed inrecirculation position is selected heat will not
the duct run).be wasted.
When the ducting mode is selected theTo obtain the best performance it is advisable
charcoal filter is not required.to switch on the hood a few minutes before
you start cooking and leave it running for
approximately 15 minutes after finishing.
5 |